Unable to call c# code from vbscript - ActiveX error
I am trying to call a method I have written in C# from VBScript.
I have followed just about all of the instructions I can find on the web and am still having problems.
Specifically I am getting
Error: ActiveX component can't create object
Code: 800A01AD
So far I have done the following:
- Set
ComVisible(true)
- Registered using
regasm /codebase
- Strong named my assembly
- Confirmed it is in the registry and points to the correct location
- Made the class public
- Have no static methods
- Made the method I want to call public
- Have a parameterless constructor
- Explicitly defined a GUID
My VBSc开发者_高级运维ript looks like this:
set oObject = CreateObject("TTTTTT.FFFFF.CCCCCCCCC")
My C# code looks like this:
using System;
using System.IO;
using System.Windows.Forms;
using System.Runtime.InteropServices;
namespace XXXXX.YYYYY
{
[ComVisible(true)]
[Guid("3EB62C37-79BC-44f7-AFBD-7B8113D1FD4F")]
[ProgId("TTTTTT.FFFFF.CCCCCCCCC")]
public class CCCCCCCCC
{
public void MyFunc()
{
//
}
}
}
Can anyone help?
Have you read this article: COM Interop Exposed
In the last page (3) of the article, there's a list:
- Define a .NET Interface for the methods you want to expose to COM.
- Assign a GUID to that interface with the "Guid" attribute.
- Have your class implement your interface as the first interface.
- Assign a GUID to that class with the "Guid" attribute.
- Add the
"
ClassInterface(ClassInterfaceType.None)
" attribute to prevent regasm/tlbexp from creating an empty default interface. - Hard-code a specific version number in your AssemblyVersion attribute.
- Create a strong-name key pair for your assembly and point to it via the AssemblyKeyFile attribute.
- Add your assembly to the GAC,
- Register your assembly for COM by using the REGASM command along with the "/tlb" option to generate a COM type library.
I'm not sure if the GAC and ClassInterfaceType.None
are the missing pieces of your puzzle, you might want to give it a try. Good luck!
There isn't anything really wrong with your code and you followed the correct install procedure, by the sound of it. The error code you get however clearly indicates that the script interpreter has trouble locating or loading the assembly. The best way to troubleshoot this is with SysInternals' ProcMon utility.
I ran your code without trouble, these were the most relevant entries in the ProcMon log:
22 12:04:41.1795038 PM WScript.exe 55280 RegOpenKey HKCR\TTTTTT.FFFFF.CCCCCCCCC SUCCESS Desired Access: Read
26 12:04:41.1795682 PM WScript.exe 55280 RegOpenKey HKCR\TTTTTT.FFFFF.CCCCCCCCC\CLSID SUCCESS Desired Access: Read
29 12:04:41.1796996 PM WScript.exe 55280 RegQueryValue HKCR\TTTTTT.FFFFF.CCCCCCCCC\CLSID\(Default) SUCCESS Type: REG_SZ, Length: 78, Data: {3EB62C37-79BC-44F7-AFBD-7B8113D1FD4F}
34 12:04:41.1797653 PM WScript.exe 55280 RegOpenKey HKCR\CLSID\{3EB62C37-79BC-44F7-AFBD-7B8113D1FD4F} SUCCESS Desired Access: Read
62 12:04:41.1802539 PM WScript.exe 55280 RegOpenKey HKCR\CLSID\{3EB62C37-79BC-44F7-AFBD-7B8113D1FD4F}\InprocServer32 SUCCESS Desired Access: Read
71 12:04:41.1804181 PM WScript.exe 55280 RegQueryValue HKCR\CLSID\{3EB62C37-79BC-44F7-AFBD-7B8113D1FD4F}\InprocServer32\(Default) SUCCESS Type: REG_SZ, Length: 24, Data: mscoree.dll
824 12:04:41.2425662 PM WScript.exe 55280 RegQueryValue HKCR\CLSID\{3EB62C37-79BC-44F7-AFBD-7B8113D1FD4F}\InprocServer32\1.0.0.0\CodeBase SUCCESS Type: REG_SZ, Length: 124, Data: file:///c:/projects/ClassLibrary2/obj/Debug/ClassLibrary2.DLL
... Lots of .NET keys...
1239 12:04:41.2970169 PM WScript.exe 55280 CreateFile C:\projects\ClassLibrary2\obj\Debug\ClassLibrary2.dll SUCCESS Desired Access: Read Attributes, Disposition: Open, Options: Open Reparse Point, Attributes: n/a, ShareMode: Read, Write, Delete, AllocationSize: n/a, OpenResult: Opened
Here's a simple project with only a few steps, to get you started.
C# code:
using System;
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
[assembly:System.CLSCompliant(true)]
[assembly: ComVisible(true)]
// The following GUID is for the ID of the typelib if this project is exposed to COM
[assembly: Guid("7d9c5cd3-73d4-4ab1-ba98-32515256c0b0")]
namespace Cheeso.ComTests
{
[Guid("7d9c5cd3-73d4-4ab1-ba98-32515256c0b1")]
public class TestReply
{
public string salutation;
public string name;
public string time;
}
[Guid("7d9c5cd3-73d4-4ab1-ba98-32515256c0b2")]
public class TestObj
{
// ctor
public TestObj () {}
public TestReply SayHello(string addressee)
{
return SayHello(addressee, "hello");
}
public TestReply SayHello(string addressee, string greeting)
{
string x = String.Format("{0}, {1}!", greeting, addressee);
Console.WriteLine("{0}", x);
TestReply r = new TestReply
{
salutation = greeting,
name = addressee,
time = System.DateTime.Now.ToString("u")
};
return r;
}
}
}
VBScript client code:
Function Main()
Dim obj
Dim reply
set obj = CreateObject("Cheeso.ComTests.TestObj")
Set reply = obj.SayHello("Evgeny")
WScript.Echo "Reply at: " & reply.time
Set reply = obj.SayHello_2("Evgeny", "wassup")
WScript.Echo "Reply at: " & reply.time
End Function
Main
To build:
(produce your .snk file, once)
csc.exe /t:library /debug+ /keyfile:Foo.snk /out:TestObj.dll TestObj.cs
regasm /codebase TestObj.exe
Then just run the vbscript (through cscript.exe).
Once you get the basic thing working, you can tweak it, add GAC, make the typelib explicit, add an explicit ProgId, and so on.
ps: FYI, this example shows what happens with overloaded .NET methods on a class registered for interop. There's an implicit _2 (_3, _4, etc) appended to the method name.
To make Cheeso's example work on a 64-bit platform, make sure you invoke CScript.exe as:
%windir%\SysWOW64\cscript.exe test.vbs
Reference: Cannot use CreateObject from VB scripts on Windows 7 x64
May be, all of your problems are caused by VS. Try to compile your library from the command line by typing
csc.exe /t:library AClass.cs /keyfile:Foo.snk - produce your key file with VS!
regasm /codebase /tlb AClass.dll
VS are adding some stuff like /warn: /noconfig and so on, and also it adding references to another assemblies like System.Core and so on, and sometimes causes the erros. For me, compiling from csc worked.
精彩评论