How do you transfer a binary file via Connect:Direct NDM?
I'm trying to submit a binary file, in this case, an Excel file from my local server (Solaris server with Mainframe rehosting software) using Connect:Direct NDM to a destination server (Mainframe).
Here are the environment values I set:
SODETFL "DetailedReport.xls"
SODDETNDM "FIN.REPORT(+1)"
TDCOPTS ":DATATYPE=BINARY:XLATE=NO:STRIP.BLANKS=NO"
Here is the NDM configuration I use:
ASSGNDD ddname='SYSIN' type='INSTREAM' << !
SIGNON 00260005
SUBMIT PROC=COPYFILE - 00270005
JOBNAME=JOB00001 - 00280005
PNODE=SERVER001 - 00290005
SNODE=NDMIDS - 00300005
SNODEID=(xxxxxx,xxxxxx) - 00310005
HOLD=NO - 00320005
NOTIFY=CCACTD - 00330005
NODE=, - 00360005
DSN1=${SODDETFL} - 00370005
DSN2=${SODDETNDM} -
DCBINFO='dcb=(dsorg=ps, recfm=vb, lrecl=1504)' - 00385005
DISP1=NEW, - 00390005
DISP2=CATLG,DELETE - 00400005
UNIT=BATCH - 00410005
SYSOPTS=${TDCOPTS} - 00440005
AEFAJOB=PSIAPNB5
SEL PROC WHERE (QUEUE=A) TABLE 00450005
SIGNOFF 00460005
I'm able to send text files via NDM all day long, no problems there. However, it seems that binary is a bit more difficult. When I try w开发者_StackOverflow社区ith the above configuration, I get the following error:
Completion Code => 8
Message Id => XCPS009I
Short Text => Read buffer too small. Possibly src reclen > dest reclen.
Ckpt=>Y Lkfl=>N Rstr=>N Xlat=>Y Scmp=>N Ecmp=>Y Ecpr=>0.00 CRC=>N Zlvl=>1 win=>13 Zmem=>4
Can anyone shed some light as to how I can go about submitting a binary file via NDM?
Off the cuff... Try changing RECFM=VB to RECFM=U and specify a BLKSIZE= instead of a LRECL=
This is really not all that different from how executable load modules are stored on the mainframe except you don't want the file to be a PDS dataset. I'm not at my office right now and I think I have some examples of NDM that transmit load modules that I can look-up if this suggestion doesn't work but I think it will.
Give this suggestion a shot and if it still doesn't fly let me know.